Coupled fluid, structural and thermal engineering
Fluid, structure and heat solved as one exchange, not three separate reports.
CFD, FEA, thermal and coupled workflows, with mesh verification. Flow, structure and heat set up from one declared study, meshed in an isolated worker and judged against written verification bars.
Flow, structure and heat set up from one declared study, meshed in an isolated worker and judged against written verification bars.
Flow losses, heat, stress and stiffness from industrial solvers, set up from one declared study.
Three-mesh refinement studies with the Grid Convergence Index on record.
Fluid and solid solved together, with interface heat balance closed and on record.
Partitioned, implicitly coupled fluid and structure, verified against published reference solutions.
Measured · Reproduced benchmark
2.175 % GCI (published 2.2 %)
Celik et al.'s worked example returns an observed order of 1.534 (published 1.53), an extrapolated value of 6.1685 (published 6.1685) and a GCI of 2.175 % (published 2.2 %). Non-monotone triples are rejected, not reported.
Measured · Verification tests
≤ 0.44 % error vs analytic solutions (statics)
Cantilever 0.44 %, Kirsch plate 0.17 %, Lamé bore 0.030 %; modal, clamped and free-free, within 0.30 %; thermal manufactured solution with observed order 3.06 against formal 3; transient time order 0.99 against formal 1.
Measured · Coupled analysis
0.0023 % interface heat balance closure
Finite-volume flow and finite-element solid, coupled implicitly and converged in 7 coupling iterations. Against the published baseline: total-pressure loss within 0.01 %, outlet mean temperature within 0.03 %. Interface heat balance closed to 0.0023 % on the inner wall and 0.00012 % on the outer wall.
Measured · Coupling verification
1.2 × 10⁻⁴ pressure, relative L2
A pipe split between two flow participants: pressure within 1.2 × 10⁻⁴ and velocity within 1.2 × 10⁻⁵ relative L2 of the published reference over 10 windows, with flow closure of 1 × 10⁻⁵.
Measured · Coupling verification
≤ 5.5 % agreement with reference (relative L2)
Dynamic finite-element tube in internal flow, implicitly coupled, against the published reference: fluid force within 1.55 %, solid displacement increment 2.0 %, mapped force 2.2 %, fluid-node displacement 5.5 %.
TensorLynx is built and run by the engineers who use it on client work. Start with one geometry and one question; results, reports and evidence are delivered through your TensorLynx client portal.
Send a geometry, the objective and the constraints. We tell you which route answers it, what it needs from you, and what you will get back.
A fixed-scope study on your own case with written acceptance criteria agreed up front: physics, sensitivities, optimisation and full-model verification.
Verification gates and trained surrogates set up around your product family, so the next design cycle starts where the last one ended.
Your engineers work in TensorLynx themselves, onboarded on your own cases, with OLTRION specialists behind them.