CAD in, CAD out
Declared design variables
Design families and sweeps
One engineering loop, five capability pillars
TensorLynx is OLTRION's engineering simulation and optimisation platform: one browser application with workspaces for geometry, simulation, design and optimisation, AI, results and history. Five capability pillars carry a design from the first parametric sketch to a verified, documented decision.
The five pillars
CFD and structural FEA
Mesh refinement and discretisation error
Conjugate heat transfer
Fluid-structure interaction
Coupled fluid, structural and thermal engineering · Mesh refinement and numerical verification
Adjoint shape optimisation
Gradient verification
Gradient-based and surrogate-based MDAO
Pareto fronts and candidate selection
Design of experiments and sensitivity
Adjoint-based shape optimisation · Sensitivity analysis and gradient verification · Multidisciplinary design optimisation (MDAO) · Pareto-based candidate selection
Surrogates with calibrated uncertainty
Full-field reduced-order prediction
Multi-fidelity optimisation
Surrogate modelling and uncertainty assessment · Full-field reduced-order prediction · Multi-fidelity optimisation
Re-run before recommending
Written verification rules
Reproducibility record and reports
Engineering history and provenance
High-fidelity reassessment of optimised designs · Reproducibility, provenance and engineering history
Six workspaces, one model, one record
Geometry · Simulation workflow (including coupled physics) · Design & optimisation · AI/ML workflow · Results analysis · History and reports. Below, the eight steps of a design study in the Design & optimisation workspace.
Model. The analyses and their connections, discovered from the case and confirmed by the engineer. Roles are assigned, never guessed from variable names.
Geometry. The shape and its parametrisation. The recorded S-duct design was exported to CAD and read back to a volume difference of 1.46e-14.
Mesh. Generated in an isolated worker from engineering targets. The improvement is re-measured on a second mesh before anyone relies on it.
Parameters. Every design variable is declared once with its unit, bounds and default, and the interface builds its controls from that declaration.
Responses. The objective, the constraints and how each value is judged. A failed run stays failed; it never becomes a number in a model.
Study. Goal, design space, disciplines and method are one saved document. A template is read, never executed.
Run. The execution plan, launch and live progress. Every run ends with a verdict from written rules; an unmeasured check reads Unknown, never Pass.
Results. Results, report and history. Measured One operating point; the best design sat at the edge of the parameter box in three of four parameters, and the report says so.
From a chain of tools to one accountable loop
| Question in the design review | A typical toolchain | With TensorLynx |
|---|---|---|
| Is this AI prediction good enough? | A number, often without a confidence measure | A label and confidence, or a withheld prediction and a solver run |
| Can we trust the gradient that drove the shape? | Assumed correct | Checked against finite differences; "Direction-checked" is never sold as "Verified" |
| Was the optimised design re-checked? | Sometimes, by hand, later | Re-run on the full model before it is called Verified |
| Is the mesh good enough? | Judged by eye | Refinement studies with a Grid Convergence Index on record |
| What happened to the failed runs? | Dropped, or filled with a default | Recorded as failed, never turned into numbers in a model |
| Can we reproduce this in a year? | If someone kept the files | Sealed run records; reports refuse untraceable claims |
Bring us the design question. Leave with a verified answer and the record behind it.
TensorLynx is built and run by the engineers who use it on client work. Start with one geometry and one question; results, reports and evidence are delivered through your TensorLynx client portal.
Feasibility review
Send a geometry, the objective and the constraints. We tell you which route answers it, what it needs from you, and what you will get back.
Pilot study
A fixed-scope study on your own case with written acceptance criteria agreed up front: physics, sensitivities, optimisation and full-model verification.
A workflow built for your product
Verification gates and trained surrogates set up around your product family, so the next design cycle starts where the last one ended.
Platform access for your team
Your engineers work in TensorLynx themselves, onboarded on your own cases, with OLTRION specialists behind them.